blockage of venting system. When using snow blowers,
make sure snow is not directed towards vent termina-
tion area.
The TDV series is considered a “special vent system”.
Check with local codes or in the absence of same, with
CSA B149.1 installation codes regarding special vent
termination clearances.
NOTICE: Flexible and rigid vent system components
are not interchangable unless otherwise specified in the
venting instructions.
NOTICE: Additional venting information regarding
clearances, terminal locations, and safety information is
contained in the installation and operationg instructions
packaged with the appliance.

3³⁄₈" (86mm)

7⁷⁄₈"

(200mm)

8"

(203mm)

9¹⁄₈"

(232mm)

T193

offset and rise elbows

12/5/03 djt

TDV45S 45°

Elbow

90° Elbow

B

A

T194

vent offset

12/5/03 djt

Vent Offset @ 45°

T193

45°

Installed

Vent Pipe

True Length

“A”

“B”

Component

Gain

Rise

Run

TDV6

4”

2¹¹⁄₁₆”

2¹¹⁄₁₆”

(102mm)

(68mm)

(68mm)

TDV12

10”

7¹⁄₁₆”

7¹⁄₁₆”

(254mm)

(179mm)

(179mm)

TDV18

16”

11⁵⁄₁₆”

11⁵⁄₁₆”

(406mm)

(287mm)

(287mm)

TDV36

34”

24¹⁄₁₆”

24¹⁄₁₆”

(864mm)

(611mm)

(611mm)

TDV48

46”

32¹⁄₂”

32¹⁄₂”

(1168mm)

(826mm)

(826mm)

T194

IMPORTANT: Do not mix vent system compo-
nents with components for other vent systems.

NOTE: Use only venting systems and components
as certified with the appliance. Use of uncertified vent
systems or components will void the warranty and may
compromise the operation of the fireplace, its systems,
and components as certified with the appliance. Use
of uncertified vent systems or components will void the
warranty and may compromise the operation of the
fireplace.

Through the Roof (Vertical) Venting

When the venting penetrates a roof the system must be
insalled in accordance with the current CSA B149.1 in-
stallation code (in Canada) or the current National Fuel
Gas Code, ANSI Z223.1/NFPA 54 (in U.S.A.). SEE
CHART FOR VERTICAL TERMINATION LOCATION.

Elbows & Offsets - General

Each installation assures the use of one 45° elbow hori-
zontal or vertical (off top of unit).

Sidewall (Horizontal) Venting Information

1. Make sure fireplace location and termination location

are consistent with requirements for terminations
and vent runs.

2. Secure unit to the floor.
3. Locate vent opening in wall. Maintain 2” (51 mm)

clearance to top of vent from combustibles. Install
wall thimble per instructions supplied with Horizontal
Vent Kit. Refer to Page 14, Figures 19 and 20 for
wall thimble installation.

4. Attach vent components beginning with a TDV45S

elbow. Apply high temperature sealant to the out-
side leading edge of the fireplace flue pipe, then
install the TDV45S starter elbow and secure it to the
fireplace with the three (3) screws (provided) through
the outer pipe flange and into the fireplace 7” (178 mm)
dia. starter flange.

T196

Horizontal takeoff

12/5/03 djt

Screw Location

Apply Sealant

to Flue Pipe

Horizontal

Take Off

Illustrated

T196

Fig. 27 Apply high temperature sealant to outside of the flue
pipe.