Temco DV1000/1200/1400 Series

76657

Defective thermocouple.

Verify that thermocouple is not kinked or damaged.

(mv Plus systems)

Check open circuit voltage of thermocouple. Voltage

should be between 18mv and 28mv. If voltage is

less than 14mv, replace thermocouple.

Defective thermo-generator.

After the pilot has been lit for approximately three

(Millivolt system)

minutes, and only the thermo-generator wire con-

nected to the main operator head, measure the volt-

age across TPTH and TP. This open circuit voltage

should be between 500mv and 750mv. Tune the

pilot adjustment screw until the mv reading falls

within these parameters. (Counter-clockwise

increases mv reading, clockwise decreases)

Defective safety magnet.

Verify operation of safety magnet in the following

(mv Plus systems)

manner.

(A) Depress and hold pilot button.

(B) Verify open-circuit thermocouple voltage as de-

scribed in previous step.

(C) Reconnect thermocouple to valve.

(D) Measure the Millivoltage between the solder

button on the base of the safety magnet, and the

valve body. If the mv reading is above 6mv for

vented appliances, or 8.5 mv for un-vented

appliances, and the safety magnet does not hold,

replace the valve.

(E) If closed circuit mv reading is the same as the

open circuit reading, the coil is electrically open.

Replace the valve.

Defective Safety Magnet

Verify operation of safety magnet in the following

(Millivolt system)

manner.

(A) Remove all wires from the terminals of the main

operator.

(B) Measure the electrical voltage between the term-

inals TPTH and TP. If the voltage is above 110mV

and the safety magnet does not hold, replace the

valve.

Pilot orifice blocked.

Replace orifice with a new orifice of the exact size

and type.

Pilot drops out.

Wrong pilot orifice.

Replace the orifice with a new orifice supplied

specifically for the appliance and gas type in

question.

No gas to main burner

Low gas pressure to appliance. With the main burner functioning, adjust the inlet

pressure regulator to supply gas to the appliance

within the design parameters of the appliance manu-

facturer. (Typically 7”NG, 11”LPG).

Pilot not lit.

Light pilot and wait for thermo-generator to heat up

sufficiently to power the main operator. If pilot fails

to light, or hold, refer to above sections.

Control knob not in ON

Rotate OFF/PILOT/ON control knob to the ON posi-

position.

tion.

Thermostat/wall switch

Thermostat not in ON position.

Turn thermostat ON, and adjust temperature control

will not cycle main

to call for heat.

burner.

Problem

Possible Cause

Solution