5.2 Known

problems

When using the debug interface through the level-converter on the SmartRf04EB. (Shown in
Figure 1 and Figure 2) it might become unstable. This problem is more likely to occur a low
voltages or with crosstalk in the cable at high interface speed.

First make sure that the 10 pin flat cable used to connect the CC2511 USB Dongle to the
SmartRF04EB is as short as possible.
Next it might be necessary to reduce the debug interface speed in order to achieve stable
operation.
In the IAR workbench do the following:

• Highlight the project name by clicking on it in the “Files” window. (See Figure 6)

• Go to Project -> Options…

• Select the Category “Chipcon”

• Click on the “Target” tab.

• Check the “Reduce interface speed” option. (See Figure 7)


Highlight the

project name

Figure 6: Highlight the project name


Check the

“Reduce interface

speed” option.

Figure 7: Reduce interface speed

SWRU082 Page 8 of 24