Warning, 2 periodic maintenance – Toshiba 2000 User Manual

Page 52

Advertising
background image

Chapter 4 Maintenance

Computer module C2PU37 User’s Manual

32

4.2

Periodic Maintenance

Check the following items periodically (once every six month is recommended). Also
check these items when the surrounding condition or environment is changed.

Item

Inspection Description

Action

Power supply voltage
(measure at the power supply
terminal of the module)

AC85 - 132VAC/170 -
264VAC

Check for loose power supply
terminal screws

Must be secure

Power supply related

Check for damaged cables

Must not be damaged

Check that the base unit is
securely in place

Must not be loose

Check that each module is
securely in place

Must not be loose

Installation

Check for loose connector in
front of the module and
damaged cables

Must not be loose or
damaged

Measure voltage of each I/O
terminal

Must be within specification

Check the input status LED

Must turn ON normally

Check the output status LED

Must turn ON normally

Check that the I/O terminal is
secure

Must not be loose

Check that the terminal
screws are secure and not
touching each other

Must not be loose or touching
each other

I/O module related

Check for damaged cables

Must not be damaged

Environment

Check the temperature,
humidity, vibration, and dust

Must be within installation
environment specification

C2 built-in Litium battery

Should be replaced after 10
years by C2 overhaul

PS694 battery

Should be replaced
after 3 years (Ni-Cd battery)
after 1 year (Ni-MH battery)

Other battery

Should be replaced after two
years

Battery related

Check that the battery
connector is connected
securely

Must be secure


WARNING

• Do not attempt to disassemble, modify, or repair.

This can cause electrocution, fire, or injury.
Contact the Toshiba service desk for repair.


Advertising