Draining product from the freezing cylinder, Rinsing, Cleaning – Taylor 161 User Manual

Page 21

Advertising
background image

17

Model 161

Operating Procedures

Draining Product From the

Freezing Cylinder

Step 1

Press the AUTO key to cancel operation. Press the

MIX REF key to cancel hopper refrigeration. These

operations should be cancelled as far ahead of

cleaning time as possible. This will allow frozen

product to soften for easier cleaning.

Note: Non--Softecht machines: Place the power

switch in the OFF position as far ahead of cleaning

time as possible. This will allow frozen product to

soften for easier cleaning.

Step 2

Lift the hopper cover. Remove the air tube and mix

level float. Take them to the sink for cleaning.

Step 3

With a sanitized pail beneath the door spouts, place

the power switch in the WASH position and open the

draw valves. When all the product stops flowing from

the door spouts, close the draw valves and place the

power switch in the OFF position. If local health codes

permit, empty the rerun into a sanitized stainless steel

rerun can. Cover the container and place it in the

walk-in cooler.

Repeat Steps 1 through 3 for the second freezing

cylinder.

ALWAYS FOLLOW LOCAL HEALTH CODES.

Rinsing

Step 1

Pour one gallon (3.8 liters) of cool, clean water into the

mix hopper. With the brushes provided, scrub the mix

hopper, and the mix inlet hole.

Note: Non--Softecht machines: Scrub the mix

level float stem.

Step 2

With a pail beneath the door spouts, press the WASH

key and open the draw valves.

Note: Non--Softecht machines: Place the power

switch in the WASH position.

Step 3

Drain all the rinse water from the freezing cylinder.

When the rinse water stops flowing from the door

spout, close the draw valves and press the WASH key

to cancel.

Note: Non--Softecht machines: Place the power

switch in the OFF position to cancel.

Repeat this procedure until the rinse water being

drawn from the freezing cylinder is clear.

Repeat Steps 1 through 3 for the second freezing

cylinder.

Cleaning

Step 1

Prepare one gallon (3.8 liters) of an approved cleaning

solution (example: Kay-5r). USE WARM WATER

AND FOLLOW THE MANUFACTURER’S SPECIFI-

CATIONS.

Step 2

Pour the one gallon (3.8 liters) of cleaning solution into

the mix hopper and allow it to flow into the freezing

cylinder.

Step 3

While the solution is flowing into the freezing cylinder,

brush-clean the mix hopper, mix level float stem and

mix inlet hole.

Step 4

Press the WASH key. This will cause the cleaning

solution in the freezing cylinder to agitate.

Note: Non--Softecht machines: Place the power

switch in the WASH position.

Step 5

Place an empty pail beneath the door spouts and raise

the draw valve. Draw off all the cleaning solution.

When the solution stops flowing from the door spouts,

close the draw valves. Press the WASH key to cancel.

Note: Non--Softecht machines: Place the power

switch in the OFF position to cancel.

Repeat Steps 1 through 5 for the other side of the

machine.

Advertising