Transcend Information SSD25S User Manual

Page 12

Advertising
background image

T

T

T

S

S

S

8

8

8

G

G

G

S

S

S

S

S

S

D

D

D

2

2

2

5

5

5

S

S

S

-

-

-

S

S

S

T

T

T

S

S

S

1

1

1

6

6

6

G

G

G

S

S

S

S

S

S

D

D

D

2

2

2

5

5

5

S

S

S

-

-

-

S

S

S

/

/

/

M

M

M

T

T

T

S

S

S

3

3

3

2

2

2

G

G

G

S

S

S

S

S

S

D

D

D

2

2

2

5

5

5

S

S

S

-

-

-

S

S

S

/

/

/

M

M

M

T

T

T

S

S

S

6

6

6

4

4

4

G

G

G

S

S

S

S

S

S

D

D

D

2

2

2

5

5

5

S

S

S

-

-

-

S

S

S

/

/

/

M

M

M

T

T

T

S

S

S

1

1

1

2

2

2

8

8

8

G

G

G

S

S

S

S

S

S

D

D

D

2

2

2

5

5

5

S

S

S

-

-

-

M

M

M

T

T

T

S

S

S

1

1

1

9

9

9

2

2

2

G

G

G

S

S

S

S

S

S

D

D

D

2

2

2

5

5

5

S

S

S

-

-

-

M

M

M

2.5” Solid State Disk

Transcend Information Inc.

V1.08

12

for 54.6us (2048 nominal Gen1 Dword times) without a response from the host as determined by detection of ALIGNP

primitives received from the host, the device assumes that the host cannot communicate at that speed. If additional

speeds are available the device tries the next lower supported speed by sending ALIGNP Dwords at that rate for

54.6 us (2048 nominal Gen1 Dword times.) This step is repeated for as many slower speeds as are supported. Once the

lowest speed has been reached without response from the host, the device enters an error state.

7. Host locks – after detecting the COMWAKE, the host starts transmitting D10.2 characters at its lowest supported rate.

Meanwhile, the host receiver locks to the ALIGN sequence and, when ready, returns the ALIGN sequence to the device at

the same speed as received. A host shall be designed such that it acquires lock in 54.6us (2048

nominal Gen1 Dword times) at any given speed. The host should allow for at least 873.8 us (32768 nominal Gen1 Dword

times) after detecting the release of COMWAKE to receive the first ALIGNP. This ensures interoperability with

multi-generational and synchronous designs. If no ALIGNP is received within 873.8 us (32768 nominal Gen1 Dword

times) the host restarts the power-on sequence – repeating indefinitely until told to stop by the Application layer.

8. Device locks – the device locks to the ALIGN sequence and, when ready, sends SYNCP indicating it is ready to start

normal operation.

9. Upon receipt of three back-to-back non-ALIGNP primitives, the communication link is established and normal operation

may begin.

COMINIT

COMINIT always originates from the drive and requests a communication initialization. It is electrically identical to the

COMRESET signal except that it originates from the device and is sent to the host. It is used by the device to request a

reset from the host in accordance to the sequence shown in Figure 6, below.

Advertising
This manual is related to the following products: