Transcend Information SSD25S User Manual

Page 21

Advertising
background image

T

T

T

S

S

S

8

8

8

G

G

G

S

S

S

S

S

S

D

D

D

2

2

2

5

5

5

S

S

S

-

-

-

S

S

S

T

T

T

S

S

S

1

1

1

6

6

6

G

G

G

S

S

S

S

S

S

D

D

D

2

2

2

5

5

5

S

S

S

-

-

-

S

S

S

/

/

/

M

M

M

T

T

T

S

S

S

3

3

3

2

2

2

G

G

G

S

S

S

S

S

S

D

D

D

2

2

2

5

5

5

S

S

S

-

-

-

S

S

S

/

/

/

M

M

M

T

T

T

S

S

S

6

6

6

4

4

4

G

G

G

S

S

S

S

S

S

D

D

D

2

2

2

5

5

5

S

S

S

-

-

-

S

S

S

/

/

/

M

M

M

T

T

T

S

S

S

1

1

1

2

2

2

8

8

8

G

G

G

S

S

S

S

S

S

D

D

D

2

2

2

5

5

5

S

S

S

-

-

-

M

M

M

T

T

T

S

S

S

1

1

1

9

9

9

2

2

2

G

G

G

S

S

S

S

S

S

D

D

D

2

2

2

5

5

5

S

S

S

-

-

-

M

M

M

2.5” Solid State Disk

Transcend Information Inc.

V1.08

21

68 0078h

F

Minimum PIO transfer cycle time with IORDY flow control

69-70 0000h

Reserved

71-74 0000h

Reserved for the IDENTIFY PACKET DEVICE command

75 0000h


F

Queue depth
15-5 Reserved
4-0 Maximum queue depth – 1

76 0206h


F
F
F

F
F
F

Serial ATA Capabilities
15-11 Reserved for Serial ATA
10 1 = Supports Phy Event Counts
9 1 = Supports receipt of host initiated power management requests
8 1 = Supports the NCQ feature set
7-3 Reserved for Serial ATA
2 1 = Supports SATA Gen2 Signaling Speed (3.0Gb/s)
1 1 = Supports SATA Gen1 Signaling Speed (1.5Gb/s)
0 Shall be cleared to zero

77 0000h

Reserved for Serial ATA

78 0008h


F

F
F
F
F
F

Serial ATA feature supported
15-7 Reserved for Serial ATA
6 1 = Device supports Software Settings Preservation
5 Reserved for Serial ATA
4 1 = Device supports in-order data delivery
3 1 = Device supports initiating power management
2 1 = Device supports DMA Setup auto-activation
1 1 = Device supports non-zero buffer offsets
0 Shall be cleared to zero

79 0000h


V

V
V
V
V
F

Serial ATA feature enabled
15-7 Reserved for Serial ATA
6 1 = Software Settings Preservation enabled
5 Reserved for Serial ATA
4 1 = In-order data delivery enabled
3 1 = Device initiated power management enabled
2 1 = DMA Setup auto-activation enabled
1 1 = Non-zero buffer offsets enabled
0 Shall be cleared to zero

80 00F0h


F
F
F
F
F
F
F
F

Major version number 0000h or FFFFh = device does not report version
15 Reserved
14 Reserved for ATA/ATAPI-14
13 Reserved for ATA/ATAPI-13
12 Reserved for ATA/ATAPI-12
11 Reserved for ATA/ATAPI-11
10 Reserved for ATA/ATAPI-10
9 Reserved for ATA/ATAPI-9
8 Reserved for ATA/ATAPI-8
7 1 = supports ATA/ATAPI-7

Advertising
This manual is related to the following products: