Cleaning

To keep your HY-5G Steamer in proper working condition, use the following procedure to clean the unit. This
regular cleaning will reduce the effort required to clean the steam generator and cavity.

A. Suggested Tools

1.

Mild detergent

2.

Stainless steel exterior cleaner such as
Zepper®

3.

Steam generator de-liming agent, such as
Groen Delimer Descaler (Part Number
114800),
commercial Lime-Away® (not the
store brand for residential use) or an equivalent.
A liquid de-liming agent will be easier to use than
crystals or powders. See the warning about
chlorides, below

4.

De-greaser, such as EncompasS®, Malone 34®,
Puritan Puribrute®, or Con-Lie®

5.

Cloth or sponge

6.

Plastic wool or a brush with soft bristles

7.

Spray bottle

8.

Measuring cup

9.

Nylon pad

10. Towels
11. Plastic disposable gloves
12. Funnel

B. Procedure

1.

Exterior Cleaning

a.

Prepare a warm solution of the mild detergent
as instructed by the supplier. Wet a cloth with
this solution and wring it out. Use the moist
cloth to clean the outside of the unit. Do not
allow freely running liquid to touch the
controls, the control panel, any electrical part,
or any louver on the side or rear panels.

b.

To remove material which may be stuck to the
unit, use plastic wool, a fiber brush, or a plastic
or rubber scraper with a detergent solution.

c.

Stainless steel surfaces may be polished with a
recognized stainless steel cleaner such as
Zepper®.

WARNING

DISCONNECT THE POWER SUPPLY
BEFORE CLEANING THE OUTSIDE OF
THE STEAMER.

KEEP WAT ER AND CLEANING
SOLUTIONS OUT OF CONTROLS AND
ELECTRICAL COMPONENTS. NEVER
HOSE OR STEAM CLEAN ANY PART OF
THE UNIT.

DON’T MIX DE-LIMING AGENTS (ACID)
W I T H D E- G R EAS E R S ( AL K AL I )
ANYWHERE IN THE UNIT

A V O I D C O N T AC T W I T H A N Y
CLEANERS, DE-LIMING AGENT OR DE-
GREASER AS RECOMMENDED BY THE
SUPPLIER. MANY ARE HARMFUL.
READ THE WARNINGS AND FOLLOW
THE DIRECTIONS!

EVEN WHEN THE UNIT HAS BEEN SHUT
OFF, DON’T PUT HANDS OR TOOLS
INTO THE COOKING CHAMBER UNTIL
THE FAN HAS STOPPED TURNING.

DON’T OPERATE THE UNIT UNLESS
THE REMOVABLE PARTITION HAS
BEEN PUT BACK IN ITS PROPER
LOCATION.

DON’T USE ANY CLEANING OR DE-
LIMING AGENT THAT CONTAINS ANY
SULFAMIC AGENT, OR ANY CHLORIDE,
INCLUDING HYDROCHLORIC ACID
(HCl). TO CHECK FOR CHLORIDE
CONTENT SEE ANY MATERIAL SAFETY
DATA SHEETS PROVIDED BY THE
CLEANING AGENT MANUFACTURER
.
DON’T USE ANY CLEANING OR DE-
LIMING AGENT THAT CONTAINS MORE
THAN 30% PHOSPHORIC ACID.

IMPORTANT

DO NOT USE ANY METAL MATERIAL (SUCH AS METAL SPONGES) OR METAL IMPLEMENTS (SUCH AS
A SPOON, SCRAPER OR WIRE BRUSH) THAT MIGHT SCRATCH ANY STAINLESS STEEL SURFACE.
SCRATCHES MAKE THE SURFACE HARD TO CLEAN AND PROVIDE PLACES FOR BACTERIA TO GROW.
DO NOT USE STEEL WOOL, WHICH MAY LEAVE PARTICLES IMBEDDED IN THE SURFACE WHICH COULD
EVENTUALLY CAUSE CORROSION AND PITTING.