Om-hy-5g – Unified Brands HYPERSTEAM (2)HY-5G User Manual

Page 13

Advertising
background image

OM-HY-5G

13

Steam Generator and Cooking Chamber

On a regularly scheduled basis, or if the SERVICE
light is on, follow the simple de-liming instructions
below. This procedure should be followed for each
cavity. REMEMBER: DON’T ALLOW DE-LIMING
AGENTS TO MIX WITH DE-GREASERS.

a.

Ensure that the unit is turned on.

b.

Set the timer to “OFF”.

c.

Using a glove or towel for hand protection,
carefully open the deliming port. The port may
be hot, and a small amount of pressureless
steam may escape as you open the port.

d.

Add two cups of de-liming agent.

e.

Close the deliming port cover.

f.

Holding in the “CLEAN” button, press and
release the ON button.

g.

The clean cycle will start, and take approximately
30 minutes.

h.

When the cleaning cycle is complete, the
CLEANING light will flash and the unit will beep.

i.

Wipe out the inside of the steamer cavity.

j.

If the steamer is to be used, turn the “ON” switch
on. When READY light turns on, the steamer is
ready for operation, set the timer to the “ON”
position.

NOTES:

1.

If the clean cycle ends abruptly, the CLEANING
light will flash five times per second. This
indicates that the clean cycle was aborted.

WARNING

SHOULD A CLEAN CYCLE BE INTERRUPTED, IT
IS POSSIBLE THAT SOME CLEANING
SOLUTION IS STILL PRESENT IN THE STEAM
GENERATOR. RE-RUN THE CLEAN CYCLE
AND CONFIRM THAT THE WATER IS DRAINING.

2.

In the event of a power outage during a clean
cycle, rerun the clean cycle when the power is
restored.

3.

To abort a clean cycle, turn the “ON” switch off
for one second and turn it back on.
REMEMBER, DE-LIMING AGENT MAY STILL
BE PRESENT IN THE STEAM GENERATOR.

If the SERVICE light is on:

1.

Take the actions listed in Troubleshooting
Section of this manual. Turn the steamer off for
10 seconds and then re-start.

2.

Repeat steam generator cleaning cycle.