Ultimate Technology 500 POS User Manual

Page 32

Advertising
background image

24

Table 3. Local Mode Programming Instructions - Continued

Note: *Default Settings

Function Code(s)

Operation

Normal Indication

Remarks

21 or 31

Main Port 0 (21)
AUX Port 1 (31)
Stop Bits

1. While in programming mode, at Series 500 Keyboard numeric keypad, enter Function

Code 21 (Port 0) or 31 (Port 1).


LED (2) turns on.


2. At Series 500 Keyboard numeric keypad, enter the number of stop bits (1 or 2) per

list below.


1 = one stop bit

2 = two stop bits*


LED (2) turns off.


3. Program the next function code or exit programming mode by entering 99 on Series

500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.

22 or 32

Main Port 0 (22)
AUX Port 1 (32)
Parity

1. While in programming mode, at Series 500 Keyboard numeric keypad, enter Function

Code 22 (Port 0) or 32 (Port 1).


LED (2) turns on.


2. At Series 500 Keyboard numeric keypad, enter the applicable number (0, 1 or 2) to

select type of parity per list below.


0 = none*

1 = odd

2 = even


LED (2) turns off.


3. Program the next function code or exit programming mode by entering 99 on Series

500 Keyboard numeric keypad or by swiping the Programmer's card. If using the
optional 3-position keyswitch, move switch out of the AUX position.

Advertising