Ultimate Technology 500 POS User Manual

Page 49

Advertising
background image

41

Table 5. Remote Programming Mode Commands - Continued

OP

CODE

(HEX)

MNEMONIC/DESCRIPTION

COMMAND/ACKNOWLEDGEMENT

A3

COMMP


Communications setup for
selecting ports, baud rate, word
length, stop bits, parity, and method
of handshaking.

COMMAND: A3Pbbbbbwsph<CR>

A3

= Op Code

P

= destination port for load

bbbbb = baud rate
W

= word length 7 or 8 bits

s

= number of stop bits 1 or 2

p

= parity odd, even, or none

h

= handshaking

<CR> = terminate command (0D hex)

Port:

0 = main; 1 = AUX

Baud rate:

00300, 00600, 01200,

02400, 04800, 09600,

19200, 38400, 57600

Word length:

7 or 8

Stop bits:

1 or 2

Parity:

O = odd, E = even, N = none

Handshaking:

H = CTS/RTS, S = XON/XOFF,

B = both, N = none


ACKNOWLEDGEMENT: NONE

A4

NOTES

Used to enter up to 40 characters
of notes into RAM. Useful for
recording keyboard version and
date, etc.

COMMAND: A4xxxx-xxxx<CR>

A4

= Op Code

xx

= Note (max of 40 Characters)

<CR> = terminate command (0D hex)

ACKNOWLEDGEMENT: NONE