Ultimate Technology 500 POS User Manual

Page 54

Advertising
background image

46

Table 5. Remote Programming Mode Commands - Continued

OP

CODE

(HEX)

MNEMONIC/DESCRIPTION

COMMAND/ACKNOWLEDGEMENT

B2

SENDP


Sends data to selected port: main
serial port, auxiliary serial port, or
auxiliary keyboard port.

COMMAND: B2p...........<CR>

B2

= Op Code

p

= data destination port

<CR> = terminate command (0D hex)

p:

0 = serial port 0 (main)

1 = serial port 1 (auxiliary)

2 = keyboard port 0 (main)

3 = keyboard port 1 (auxiliary)

4 = cash drawer 1 fire

5 = cash drawer 2 fire


Where data can be ASCII or CxDx (high and
low nibble hex value) type.

ACKNOWLEDGEMENT: NONE

B3

RDERROR


Sends all error information to main
port for output.

COMMAND: B3<CR>

B3

= Op Code

<CR> = terminate command (0D hex)

Sends all error log information contained in
the non-volatile memory (NVRAM) out the
main port.

ACKNOWLEDGEMENT: NONE