Table 5. Remote Programming Mode Commands - Continued

OP

CODE

(HEX)

MNEMONIC/DESCRIPTION

COMMAND/ACKNOWLEDGEMENT

BC

CDSTATUS


Send cash drawer macros for open
and closed drawer.

COMMAND: BCp<CR>

BC

= Op Code

p

= selection control

<CR> = terminate command (0D hex)

Selection control:
A

= cash drawer 1 macros

B

= cash drawer 2 macros

C

= cash drawer 1 and 2 macros


ACKNOWLEDGEMENT:
Send back Macros for request.

BD

PORTE


Disables all data applied from the
selected port.

COMMAND: BDpx<CR>

BD

= Op Code

p

= port

0 = serial 0 main

1 = serial 1 AUX

2 = keyboard main

3 = keyboard AUX

x

= selection control

1 = enable data

0 = disable data

<CR> = terminate command (0D hex)


ACKNOWLEDGEMENT: NONE