5 nozzle replacement, 6 adjusting control knobs – Fagor 6FI-4GLSX User Manual

Page 9

Advertising
background image

INSTALLATION

UK

8

ATTENTION !

1. Checking the leakage with an open flame (e.g. with a match or a candle) is

unacceptable. It may lead to an explosion !

2. Check condition of the hose and connection tightness regularly, according to the

valid regulations.

2.5 NOZZLE REPLACEMENT

ATTENTION !

Before nozzle replacement and adjustments, disconnect the hob from the mains.

Nozzle diameters for particular gas type are shown in Table 2.

Table 2

AUX

burner

SR burner

R burner

TC burner

G 20 20 mbar

X072 Z097 Y118 K1,35

G 30/31 29/37 mbar

050 065 085 098

The hob is adjusted to the type of gas and pressure stated on the appliance's rating plate.
In the event of a change of the type of gas replace the nozzles and adjust the taps.
Before beginning these activities you must:

shut down the cock shutting off the gas supply system or cylinder from the hob,-shut
down all the taps in the hob,

disconnect the hob from the mains.

Then:

remove the burners' lids and rings,

remove the nozzles with socket wrench no. 7 and replace them with new ones in
accordance with table2,

put burners' rings and lids back,-

adjust the taps and check the connections for soundness

Fig. 12

2.6 ADJUSTING CONTROL KNOBS


ADJUSTING THE TAPS
The adjustment of a gas tap consists in setting the burner flame in the simmering position. To
adjust the taps remove all the knobs and control panel.

Advertising