Receiver specifications – Uniden MHS550 User Manual

Page 42

Advertising
background image

Uniden MHS550 Radio Owner’s Manual

40

Receiver Specifications

Unit Nominal

Limit

Sensitivity for 12dB

SINAD

MRN

μV

0.3

0.4 max.

FRS

μV

0.35

0.5 max.

FM Broadcast

μV

1.0

3.0 max.

Air

μV

1.0

30 max.

AM Broadcast

μV

1.0

2.0 max.

Squelch Sensitivity

Threshold

μV

0.1

0.25 max.

Tight

μV

0.7

2.0 max.

CTCSS/DSC Opening

SINAD

FRS

dB

8

12 max.

Audio Freq. Response

1kHz Ref.

MRN @ 500 Hz

dB

6

3 to 7

MRN @ 2000 Hz

dB

-6

-9 to -5

FRS @ 500 Hz

dB

6

3 to 7

FRS @ 2000 Hz

dB

-6

-9 to -5

Adjacent Channel

Selectivity

MRN ±25 kHz

dB

72

60 min.

FRS ±12.5 kHz

dB

40

30 min.

IM Rejection

MRN

dB

63

55 min.

Image and Supurious

Rejection

MRN

75

50 min.

Conducted Spurious Emission at the

Antenna Terminal

dBm

-65

-57 max.

Hum and Noise Ratio

MRN

dB

50

35 min.

FRS

dB

37

32 min.

AM Broadcast

dB

42

32 min.

FM Broadcast

dB

53

32 min.

Air

dB

42

32 min.

THD @ Standard Output Power (MRN)

%

1.2

10 max.

Audio Output Power @10% THD (MRN)

W

0.45

0.3 min

Oscillator Dropout Voltage (MRN)

V

2.9

3.8 max.

Current Drain @ No Signal (MRN)

mA

72

85 max.

Current Drain @ Maximum Output (MRN)

mA

220

250 max.

Advertising