Configuration: Pump > Destination 1

See MPEG-2 Configuration: Encoder > Destination 1/Destination2 on page 31.

Continuous Enable

If

Once

is selected the selected file or batch will play through to

completion and stop. If

Continuous Repump

is selected, the

selected file or batch sequence will be continuously played until
the stop button is pressed or a different file is selected. When the
file or batch has completed playing it wraps to the beginning and
plays again.

Auto Pump New File

Can be enabled or disabled to allow any file to be automatically
pumped on FTP reception. If batch mode is enabled, any file
with the identified base name will be pumped on FTP reception.
If batch mode is not enabled, any file FTP'd to the disk will be
pumped on reception. Some special cases of operation following
an FTP onto the hard drive.

• If both Batch Mode is enabled and Continuous Enable is

Continuous Repump, the FTP'd file that belongs to the series
is played when its turn is reached. If it is not part of the series,
it is not played.

• If Batch Mode is enabled and Continuous Enable is Once, all

files will be played. If the FTP'd file belongs to the series and
has a greater index than the last file played, then the FTP'd
file is played. Otherwise nothing happens.

• If Batch Mode is disabled and Continuous Enable is

Continuous Repump. The current file completes, and the new
file is played continuously.

• If Batch Mode is disabled and Continuous Enable is Once.

The current file will be completed and the FTP'd file will
start.

Pump State

Is a read only field that lets you know if the Pump is running or
stopped.