MPEG-2 Configuration

VBrick MPEG-2 Appliance Admin Guide

53

Sample Script

vbrickSlot2EncoderNetworkTransmitEnable = 2 // set enable slot 2 encoder transmit

vbrickSlot2EncoderNetworkApplySet = 2 // apply above encoder network set
* // end of a group

vbrickHDRecorderControlMode = 1 // set recorder to user controlled mode

vbrickHDRecorderControlIrEnable = 1 // disable recorder ir control
vbrickHDRecorderControlName = event1record.mpg // set recorder file name
vbrickHDRecorderControlDuration.value = 30 // set recorder duration to 30 seconds
vbrickHDRecorderControlBatchEnable = 1 // set recorder batch to disabled
vbrickHDRecorderControlApplySet = 2 // apply above recorder control sets
* // end of a group

vbrickHDRecorderControlFtpEnable = 1 // disable auto ftp after record

vbrickHDRecorderControlApplySet = 2 // apply above recorder control set
vbrickHDRecorderNetworkReceiveType = 1 // set recorder receive type to ip address
vbrickHDRecorderNetworkReceiveIpAddr = 239.22.129.3 // set recorder receive ip address
vbrickHDRecorderNetworkReceivePort = 4443 // set recorder receive port
vbrickHDRecorderNetworkApplySet = 2 // apply above recorder network sets
* // end of a group

vbrickHDRecorderOperationStart = 2 // start recording

* // end of a group

wait = 5000 // wait for 5000 milliseconds

* // end of a group

vbrickSlot1EncoderNetworkTransmitEnable = 2 // set enable slot 1 encoder transmit

vbrickSlot1EncoderNetworkApplySet = 2 // apply above encoder network set
* // end of a group

Scripting Notes

* denotes end of group.

Each group can have a maximum of six sets.

Each group must have apply sets for all normal sets.

Wait state will be alone in a group.

There is no clear command.

Script commands must start in column 1.

There is no chaining of scripts.

Comments will start with / and can be a line or the end of a command.

All scripts are executed in a strictly serial manner by a single task.

While executing a script it is possible to miss a double change of any event.

Configuration: Script Management > Auto Configuration

Auto Config lets you perform an auto-configuration via a URL script file. It is typically used
for remote configuration and troubleshooting or to configure VBrick appliances that are
behind a firewall. To configure a parameter on an appliance (or more likely a set of
parameters) you simply point the URL to a server with an .xml configuration file. This is
useful, for example, to change a reflector URL, set the audio and video rates, etc. when the
VBrick appliances are behind a firewall and cannot be accessed remotely.