Set Server Parameter Values

Note: The access right depends on the URL directory.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/

anonymous

/setparam.cgi? <parameter>=<value>

[&<parameter>=<value>…][&update=<value>][&return=<return page>]

http://<servername>/cgi-bin/

viewer

/setparam.cgi? <parameter>=<value>

[&<parameter>=<value>…][&update=<value>] [&return=<return page>]

http://<servername>/cgi-bin/

operator

/setparam.cgi? <parameter>=<value>

[&<parameter>=<value>…][&update=<value>] [&return=<return page>]

http://<servername>/cgi-bin/

admin

/setparam.cgi? <parameter>=<value>

[&<parameter>=<value>…][&update=<value>] [&return=<return page>]

PARAMETER

VALUE

DESCRIPTION

<group>_<name>

value to assigned

Assign <value> to the parameter <group>_<name>.

update

<boolean>

Set to 1 to update all fields (no need to update parameter in

each group).

return

<return page>

Redirect to the page <return page> after the parameter is

assigned. The <return page> can be a full URL path or relative

path according to the current path. If you omit this parameter, it

will redirect to an empty page.

(Note: The return page can be a general HTML file (.htm, .html)

or a VIVOTEK server script executable (.vspx) file. It cannot be

a CGI command or have any extra parameters. This parameter

must be placed at the end of the parameter list

Return:

HTTP/1.0 200 OK\r\n

Content-Type: text/html\r\n

Context-Length: <length>\r\n

\r\n

<parameter pair>

where <parameter pair> is