Owner’s manual, Venting installation – Vanguard Managed Solutions MBDV37 User Manual

Page 7

Advertising
background image

7

106497

OWNER’S MANUAL

WARNING: Read all instruc-

tions completely and thoroughly
before attempting installation.
Failure to do so could result in
serious injury, property damage
or loss of life. Operation of im-
properly installed and maintained
venting system could result in
serious injury, property damage
or loss of life.

WARNING: Seal all vent con-

nections. Seal only the outer pipe
connections with high temperature
silicone (600

°

F/316

°

C). Before join-

ing elbows and pipes, apply a bead
of high temperature silicone seal-
ant (GE RTV 106/Loctite RTV 81585)
to the male end of the elbow or
pipe. High temperature silicone
must also be used to re-seal any
connections after maintenance to
venting system.

NOTICE: Failure to follow these
instructions will void the warranty.

INSTALLATION
PRECAUTIONS

Consult local building codes before beginning
the installation. The installer must make sure
to select the proper vent system for installa-
tion. Before installing vent kit, the installer
must read this fireplace manual and vent kit
instructions.

Only a qualified service person should in-
stall venting system. The installer must fol-
low these safety rules:

• Wear gloves and safety glasses for

protection

• Use extreme caution when using ladders

or when on roof tops

• Be aware of electrical wiring locations

in walls and ceilings

The following actions will void the war-
ranty on your venting system:

• Installation of any damaged venting

component

• Unauthorized modification of the vent-

ing system

VENTING
INSTALLATION

WARNING: This gas fireplace

and vent assembly must be
vented directly to the outside.
The venting system must NEVER
be attached to a chimney serving
a separate solid fuel burning ap-
pliance. Each gas appliance must
use a separate vent system. Do
not use common vent systems.

WARNING: Horizontal sec-

tions of this vent system require
a minimum clearance of 2" from
the top of the pipe and 1" mini-
mum to the sides and bottom.
Vertical sections of this system
require a minimum of 1" clear-
ance to combustible materials on
all sides of the pipe.

• Installation of any component part not

manufactured or approved by DESA
International

• Installation other than as instructed by

these instructions

INSTALLATION PLANNING

There are two basic types of direct-vent
installation:

• Horizontal Termination

• Vertical Termination

It is important to select the proper length of
vent pipe for the type of termination you
choose. It is also important to note the wall
thickness.

For Horizontal Termination:

Select the

amount of vertical rise desired. The horizon-
tal run of venting must have 1/4" rise for
every 12" of run towards the termination.

A MDVGFK ground floor horizontal vent
kit is specifically designed for common
horizontal installations in manufactured
(mobile) homes. Additional horizontal in-
stallations are described on pages 10 and 11.
All vent kits and components are listed on
pages 15 and 16.

Continued

You may use one or two 90

°

elbows in this

vent configuration. See Horizontal Termina-
tion Configurations
on pages 10 and 11.

For Vertical Termination:

Measure the dis-

tance from the fireplace flue outlet to the
ceiling. Add the ceiling thickness, the verti-
cal rise in an attic or second story, and allow
for sufficient vent height above the roofline.
You may use one or two 90

°

elbows in this

vent configuration. See Vertical Termination
Configurations
on pages 13 and 14.

Note:

You may use two 45

°

elbows in place

of a 90

°

elbow. You must follow rise to run

ratios when using 45

°

elbows.

The MDV9K 9' vertical vent kit is specifi-
cally designed for common vertical installa-
tions in manufactured (mobile) homes. Ad-
ditional vertical installations are described
on pages 13 and 14. All vent kits and com-
ponents are listed on pages 15 and 16.

For two-story applications, firestops are re-
quired at each floor level. If an offset is
needed in the attic, additional pipe and el-
bows will be required.

You may use a chase with a vent termination
with exposed pipe on the exterior of the
house. See Installing Vent System in a Chase,
page 8.

Your Vanguard direct-vent fireplace has
been tested for a minimum 3' rise with a
maximum 10" wall thickness. The maxi-
mum horizontal run is 20' with 8' vertical
rise (see Installation for Horizontal Termi-
nation
, pages 8 and 9). The maximum ver-
tical run is 30' (see Installation for Vertical
Termination
, pages 12 and 13).

It is very important that the venting system
maintain its balance between the combus-
tion air intake and the flue gas exhaust.
Certain limitations apply to vent configura-
tions and must be strictly followed.

WARNING: Never run the vent

downward as this may cause ex-
cessive temperatures which
could cause a fire.