DIRECT-VENT FIREPLACE

®

INSTALLATION FOR
HORIZONTAL TERMINATION

1.

Determine the route your horizontal
venting will take.

Note:

The location

of the horizontal vent termination on the
exterior wall must meet all local and
national building codes and must not be
easily blocked or obstructed.

Snorkel terminations are available for
terminations requiring a vertical rise on
the exterior of the building (see Figures
9 and 10). Snorkel kit SVK is also avail-
able (see page 15). Follow the same in-
stallation procedures as used for stan-
dard horizontal terminations. If install-
ing the snorkel termination below grade
(basement applications), you must pro-
vide proper drainage to prevent water
from entering the snorkel termination
(see Figure 10). Do not back fill around
the snorkel termination.

VENTING
INSTALLATION

Continued

Figure 10 - Snorkel Termination with Drainage Pipe

Figure 9 - Snorkel Termination

WARNING: Do not recess vent

terminal into a wall or siding.

Figure 11 - Vent Pipe Connections

Female
Locking
Lugs

Male
Slots

Rigid Vent Pipe Flexible Vent Pipe

Spacer
Spring

4" Clamp

7" Clamp

4" Flex
Pipe

7" Flex
Pipe

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

,,,,,,,,,,,,,,

Adequate
Drainage

12" Minimum

Snorkel

,,,,,

,,,,,

,,,,,

,,,,,

Snorkel

NOTICE: Treatment of firestops
and construction of the chase may
vary from building type to build-
ing type. These instructions are
not substitutes for the require-
ments of local building codes. You
must follow all local building
codes .

Note:

When installing in a chase, you should

insulate the chase as you would the outside
walls of your home. This is especially im-
portant in cold climates. Minimum clear-
ance between vent pipes and combustible
materials such as insulation is 1".

After framing the chase (see Framing and
Finishing
on pages 4 and 5) install the
vent system by following the installation
instructions.

Installing Vent System in a Chase

A chase is a vertical boxlike structure built
to enclose venting that runs along the out-
side of a building. A chase is not required for
such venting.

2.

Rigid vent pipes and fittings have spe-
cial twist-lock connections. Assemble
the desired combination of pipe and el-
bows to the appliance adaptor with pipe
seams oriented towards the wall or floor.

Twist-lock Procedure:

The female

ends of the pipes and fittings have four
locking lugs (indentations). These lugs
will slide straight into matching slots on
the male ends of adjacent pipes and fit-
tings. (All connections must be sealed
with high temperature silicone sealant
as specified in the second warning on
page 7.) Push the pipe sections together
and twist one section clockwise approxi-

mately one-quarter turn until the sections
are fully locked. See Figure 11.

Note:

Horizontal runs of vent must be sup-
ported every three feet. Use wall straps
for this purpose.

Flexible vent pipe must be installed with
spacer springs every 12". See Figure 11.
All connections must be clamped tightly
and sealed with high temperature sili-
cone sealant as specified in the second
warning on page 7.