TROUBLESHOOTING

If your cooler does not work properly, please note the following suggestions
before you attempt to repair or replace the unit.

Your cooler does not work:
• Check the electrical outlet for power and that the plug is properly plugged

in.

• Check the condenser for proper cleaning.

• The circuit breaker is tripped or the fuse is blown.

Your cooler makes too much noise:
• Check that the cooler is level.


Compressor turns on and off frequently:
• The room temperature is higher than normal.

• The door is not closed completely.

• The door gasket is not sealed well.

• There is insufficient clearance around the cooler.

• The cycling frequency will reduce when all of the cans reach the set

temperature.


The following is not a malfunction:
• It is normal to hear gurgling sounds caused by the flow of refrigerant

when each cooling cycle ends.

CIRCUIT DIAGRAM

sensor

Computerized

Controller

Overload

Protector

Compressor

C

M

S

PTC Starter

Starter

S

Impedance coil

Control Enclosure

L
N
E

115V 60Hz

Li

gh

t

Advertising