9.

Input the RAID size, press Enter.

10. Press

Ctrl+E to exit the BIOS.

11. When asked Are you sure to exit(Y/N)?, press Y to exit

and reboot.

Note: If during boot the RAID BIOS reports an RAID1 set is in

Rebuild status, The rebuild will continue after boot

sequence is complete, disregard the message, continue

booting, and let the Mirror rebuild.

Rebuilding a Failed Mirror Set

When a failure to one member occurs, you will be notified either

by the RAID BIOS during boot or by the SATARAID5 GUI while

in Windows. The steps below will guide you in rebuilding a failed

mirror set.

1. Replace the failed drive with one of equal or greater

capacity, then start the computer.

2. During boot press Ctrl+S or F4 to enter the RAID BIOS.
3. Select

Create RAID Set then press Enter.

4. Select

SPARE DRIVE then press Enter.

5. Select the replacement drive then press Enter.
6. When

asked

Are You Sure(Y/N)?, press Y to confirm.

7. Press

Ctrl+E to exit.

8. When

asked

Are you sure to exit(Y/N)?, press Y to exit.

RAID 0+1 (Mirroring + Striping)

This RAID array to be used on New/Blank hard drives, do not

Advertising