Safety Upgrade Instructions

Page 5

Figure 10.Battery Replacement

Figure 9. Microswitch arm location

Important Note:
When connecting the ignition bar to
the top of the gas valve it is important
that the arm of the microswitch is
behind the ignition arm (See figure 9).

Ensure that when the ignition bar is
depressed the microswitch arm does
not pass over the top of the ignition
arm. If it does, or appears likely to
during future use, then the angle of the
ignition arm must be adjusted. Only
make the adjustment if absolutely
necessary. Do not overbend the
ignition arm.

The screw at the base of the ignition
bar must be against the ‘D’ flat on the gas valve spindle.

4. Replacing the electronic spark generator battery

Refer to figure 10.
1.

Remove the battery from the electronic spark generator. To do this simply grip the
battery at the left hand side, lift and pull to the left.

2.

Remove the old battery from the work area.

3.

Obtain a new battery
and fit this into the
electronic spark
generator. To do this
hold the battery so
that the positive
terminal is towards
the rear of the
appliance. Slide the
battery in from the
left side. When the
battery stops sliding
push it down so that
it locates against the
left-hand retainer.

Advertising