Safety Upgrade Instructions

Page 6

Figure 11. Relief panels

5. Relief Panel operation

The relief panels on the underside of the firebox should be held in place by their spring
retainers, but should be capable of opening when the pressure within the firebox becomes
too great.
• To check the operation of the

relief panels push them down
from inside the firebox. They
can be accessed behind the
lower ceramic support by first
removing the two cross logs
and front log. (See figure 11).
Push down by 40-50mm and
ensure that they open easily
and freely. There should be
no restriction.

If there is any restriction or
metallic scrapping sound then
the relief panels may be
coming into contact with the
stop plates. These are located
on the underside of the
firebox behind the relief
panels and are to ensure that
the springs are not over bent
during operation. If the relief
plate is coming into contact
with the stop plate then push
the bottom of the stop plate
towards the rear of the appliance by about 1/8

th

inch. Try the operation of the relief

plate and ensure that it closes against the base of the firebox.

It is Important that

the relief doors operate easily and freely before leaving the
appliance.