4
STEP
DO NOT STAND ON THE BELT WHEN PERFORMING AUTO-CALIBRATION
You need to access User Engineering Mode to run the auto-calibration. With the safety key in place, please hold
down SPEED DOWN and SELECT for 5 seconds. When in the User mode, “USER ENG MODE” appears in the
alphanumeric window. To access the data press the ELEVATION keys until “AUTO-CALIBRATION” appears.
To begin auto-calibration, press SELECT. The treadmill will run through minimum and maximum speed and
maximum incline. This will take 3-5 minutes. Let the treadmill perform this complete function before exiting the
Engineering Mode.
Elevation A/D appears in the left window. PWM value appears in the dot matrix window, and speed appears in
the right window. “CALIBRATION PASSED” will appear in the alphanumeric window when the auto-calibration is
complete. The treadmill will come to a complete stop and return to the start-up screen in the alphanumeric window.
AUTO-CALIBRATION