Rs-232c external control, Communication specifications, Command format – Vidikron D-ILA 80 User Manual

Page 35

Advertising
background image

35

RS-232C External Control

Control of this unit via an automation control system is possible by connecting it to this unit with a RS-232C cross cable (D-sub 9 pins). The
commands to control this unit and the response data format against the received commands are explained here. For details, please consult
your authorized dealer.

1. Communication Specifi cations

Communication specifi cation for this unit are as follows:

Baud Rate

9600/19200 bps

Data Length

8 bit

Parity

None

Stop Bit

1 bit

Flow Control

None

2. Command Format

2-1. Command data format

When sending a control command to this unit, use the following data format:

Header

: Designates the head of data and the data type.

! (21h): Assigns command to the projector

? (3Fh): Query to the projector (Asking command)

ID

:1: Identifi cation number of the projector (Factory setting is 1)

SP

: Designates the delimiter for ID, Command and Parameter. (20h)

CR

: Designates the terminal of the data. (0Dh)

Header

ID

SP

Command

SP

Parameter

CR

[

]

Header

ID

SP

Normal Termination Status

SP

Parameter

CR

[

]

* [ ] is not necessary for Asking command.

2-2. Response data format

Upon executing a control command it has received, this unit sends back the following response data to the automation control
system:

Header

: Designates the head of the data.

@ (40h): Fetches data from the projector

ID

: 1: Identifi cation number of the projector (Factory setting is 1)

SP

: Designates the delimiter for ID, Command and Parameter. (20h)

Normal Termination Status : 0 (30h)
CR

: Designates the terminal of the data. (0Dh)

Advertising