7. Initial set-up and programming (No. 24 programming)

Functions the EXES-2000 system has besides basic functions include selectable functions capable of
being freely selected by station No. 24 programming, and additional functions that can be obtained by
connecting optional equipment. To make the selectable function or additional function available,

establish No. 24 programming after making initial set-up. Once these procedures have been
completed, the initial set-up is no longer required when adding the equipment or changing the function.
All the functions available from the EXES-2000 are shown in the table on page 21.

7-1 Procedures of initial set-up and No. 24 programming

(1) Turn on SW2 switch of the memory backup battery on the CC unit.

(2) Verify

that the exchange is correctly wired and each module unit is correctly mounted in the

exchange. Then plug the power cord of the PU-200 in a wall AC outlet.

(3) Confirm

that

the

power

indicator

lamp of the CC unit in the EX-200 and the one on the FC-210 both

come on.

(4) Connect the station to No. 24 connector of the LM unit in the exchange and confirm that a brief

tone is audible continuously. The brief tone is a warning tone to indicate that the initial set-up has
not yet been made.

(5) Place

SW1 program

switch on the CC unit in the ON position.

(6) Confirm

a

dial tone is heard when depressing

of No. 24 station.

(7) Confirm that a confirmation tone is heard by dialing

10 times

(This procedure is not needed in the event of the addition or change of the function.)

(8) Register functions according to instructions on dial operation in section 7-2. Record all the

functions of each station in the station function table on page 40, which is to be retained for the
system maintenance purposes.

(9) Set

SW1 program

switch on the CC unit to OFF.