VIEWSONIC EXES-2000 User Manual

Page 40

Advertising
background image

Trouble-shooting at the time of installation

(1)

Cannot dial

All stations?

No (Specified

stations)

Yes

Switch settings for SW1 and
SW2 on LM are made properly?

Set switches

properly

Yes

Is wiring to the station correct?

Wire correctly;!

Replace station

LM

CC in

that order

Power indicator lamp on

exchange and

FC-210 is lit normally?

No

Check AC/DC fuses

Check wirings of power

cable

Yes

Each unit is mounted in a
correct position?

No

Mount them in correct
positions

Yes

Station No.24

programming is completed?

No

Make station No.24

programming

Yes

DC voltage normal?

(+5V, +24V)

No

Yes

Replace CC

Voltage becomes normal when

all the units are removed?

No

Yes

Replace CC

Replace units that cause

the voltage to return to

normal when they are removed.

– 39 –