WHISPERKOOL SERIES ADVANCED CONTROLLER

Button

Functions

ON/OFF

• The ON/OFF button turns the refrigeration system on or off. This feature does not

disconnect power from the unit. The condenser fan will continue to run in the OFF position.

In order for the power to be shut off from the unit, the power cord must be unplugged from

the wall.

Up and Down

buttons

• Use these buttons to scroll through the control panel menu.

• These also display the highest and lowest temperature sensed by the bottle probe. This

feature allows the customer instant access to the recorded data applicable to the bottle

probe temperatures, it can be easily reset to reflect current temperatures.

1. Press the “Up” arrow, or the “Down” arrow once, and the highest or lowest temperature

(Hi/Lo) sensed by the bottle probe, will be displayed.

2. To reset the Hi/Low, press and hold the “Set” button when the Hi/Low value is displayed

on the digital display, continue to hold the “Set” button until “RST” appears on the digital

display and then blinks. This will erase the past recorded temperature data history and start

recording, from the current time and temperature, forward. Temperatures displayed would

reflect bottle probe temperatures from that point in time and beyond.

3. The Hi/Low feature should be reset at initial start-up and after the cellar or cabinet has

obtained normal operating temperatures — generally 55°F.

Cellar Pre-Chill • Activate the Cellar Pre-Chill feature by pressing the “Up” button for 3 to 5 seconds, and

the CPC logo (a yelowsnowflake inside a semicircle) will be displayed on the digital display.

Terminate the CPC by pressing the “Up” button again for 3 to 5 seconds or the feature will

self-terminate after 6 hours.

1. The CPC feature may be used to pre-chill the cellar prior to loading it with warm bottles.

The feature will shift the set point down to a lower setting of 52°F, for the next 6 hours. After

the 6-hour time period, the set point will automatically return to the original set point.

Compressor

Evaporator Fan

Defrost

Energy Reduction

Button 1

Energy Reduction

Set Button

- View set point 1

- Change set point 3-5

- SET + Down = CPSM 5-7

- Reset Hi & Lo Button 3-5

Alarm

Pre-Chill Display

Condenser Fan

Cellar Pre-Chill Button 3-5

High Bottle Temp

History & Scroll Button 1

Low Bottle Temp History

& Scroll Button 1

“ON/OFF” button 1

Note: The 1 or the 3-5 stands for the amount of time (in seconds) that the button must be held.