Troubleshooting (cont.) – Vinothèque WhisperKOOL 2500 User Manual

Page 20

Advertising
background image

Page 17

GCM-01 050410

TROUBLESHOOTING (CONT.)

Door gasket not sealing correctly

If the cabinet’s cooling system is running continually without reaching the desired

temperature, the problem may lie with the door gaskets not sealing correctly.

Examine the door gasket around the entire unit.

You can also check this by turning on the cabinet’s interior light and turning off the

lighting in the room. Determine if there is an area that is not sealing properly.

If a problem exists, use the following guidelines to resolve the problem:

• Heat up the gasket with a hair dryer while using your

fingers to pull the gasket outward. Doing this for several minutes will

loosen the gasket material and increase its flexibility.

• Close the door and determine if the magnetic strip within the gasket

will seal with the metal strip on the door.

• Repeat steps until gasket seals correctly. Once it has reseated itself,

leave the doors closed for two to three hours. The seal should retain

the new shape after this process.

Door realignment

The door can be adjusted by loosening the three Allen

head bolts (easier done from the outside), securing the

top and bottom pivot hinges through slotted mount-

ing holes and moving the hinge(s) in the appropriate

direction. Re-tighten the bolts after the adjustment is
completed only after checking the level of the cabinet.

door adjust.allen wrench

Advertising