19 j104 external speaker, 20 j105 watch dog, 21 j106 tx data path – Viking 242-2009-632 User Manual

Page 118: 22 a301 compandor connections, 13 interface alarm card, 1 alarm forwarding to switch, 2 relay outputs, Figure 6-19 4 i/o j1 alarm outputs

Advertising
background image

CIRCUIT DESCRIPTION

6-46

March 1999
Part No. 001-2009-600

6.12.19 J104 EXTERNAL SPEAKER

J104 provides an external speaker connection at

the repeater site for monitoring.

6.12.20 J105 WATCH DOG

J105 enables or disables the watchdog timer for

reset. Normal operating mode is P105 jumpering
J105, pins 2/3. This jumper should not be moved or
removed.

6.12.21 J106 TX DATA PATH

Jumpers P106 and P107 connect J106, pins 1-2

and 3-4 for external options that require the Tx Data
signal. Normal operation connects J106, pins 2-3 and
4-5.

6.12.22 A301 COMPANDOR CONNECTIONS

EP101

Expand In

EP102

Expand Out

EP103

Ground

EP104

Compress Out

EP105

Compress IN

EP106

+5V

6.13 INTERFACE ALARM CARD

This card stores the information required to oper-

ate the alarms designated in the programming of the
repeater. Data is received on the address bus from the
MPC for the; operation to perform, the processor and
external memory, open and close relays on the outputs,
and receive alarm indications on the inputs. This
information is either routed to external devices or
alarm outputs can be wired to alarm inputs.

The Interface Alarm Card (IAC) contains 4-input

contacts and 4-output contacts. The 4- inputs can be
disabled, energized or de-energized. The 4-output
relays are dry contacts that have a 2A rating and can
be either normally open or normally closed.

The electromechanical relay outputs are com-

prised of eight SPDT (normally open) relays. The
relays are all open at power-on. Data to the relay is
latched by a write to the base address.

The IAC activates relays when alarm trigger

events occur. The IAC monitors for alarm activity in
the system and can set the various output relays as
defined by the user during programming. When an
external alarm is set it can be monitored from a remote
location. Refer to Section 4.7.2 for alarm program-
ming.

6.13.1 ALARM FORWARDING TO SWITCH

Repeater alarms are routed to the CIB (Channel

Interface Bus) to be detected by the Call Processor and
the System and Subscriber Manager.

6.13.2 RELAY OUTPUTS

The alarm relay outputs are provided via a termi-

nal block on the back of the repeater (see Figures 6-19
and 6-20).

The alarm outputs are on the terminal block at the

rear of the repeater.

Figure 6-19 4 I/O J1 ALARM OUTPUTS

25

26

ALA

RM

IN

AL

AR

M O

UT

I/0

13

1

2

4-

3-

3+

4+

3+

4-

3-

4+

IA

C

41

EX

TO

U

T1

CO

M

49

CO

M

5

0

TX

D I

N

RX

V

O

IC

E

TX

V

OI

CE

BRX

WB

AND

CO

M

M

6

SQ

EN

E

XT

RE

Q

2

CO

M

1

7

SY

NC

IN

TX

D

O

UT

CO

M

53

CO

M

5

4

CO

M

55

Advertising