SERVICING

8-3

March 1999

Part No. 001-2009-600

Measure the prescaler input frequency at f

in

, pin

11. Then measure the output frequency at TEST 2,
pin 13 and calculate the divide number. If the VCO is
not locked on frequency, the divide number should
still be correct. The measured frequencies may not be
exactly as calculated due to counter accuracy and res-
olution limitations.

NOTE: The counter should be connected to a high
stability reference oscillator.

Example: Channel 300, VCO locked on frequency

845.550 MHz (pin 11)

÷

13.200 (pin 13) = 64.0568

8.2.5 CALCULATING "N " AND "A " COUNTER

DIVIDE NUMBERS

"N" Counter

N Counter Divide Number =
Integer (VCO Freq. (MHz)

÷

0.8)

Example: Channel 200 (receive)

VCO freq = 898.500 - 52.95 = 845.550 MHz

N Cntr Div No = 845.550

÷

0.8 = 1056.9375

Integer (whole no.) of 1056.9375 = 1056

Example: Channel 200 (transmit)
N Cntr Div No = 937.500

÷

0.8 = 1171.8750

Integer (whole no.) of 1171.8750 = 1171

"A" Counter

A Counter Divide Number =
(VCO freq (MHz)

÷

.0125) - (N Cntr Div No x 64)

Example: Channel 200 (receive)

A Cntr Div No = (845.550

÷

.0125) - (1056 x 64)

= 67,644 - 67,584
= 60

Example: Channel 200 (transmit)

A Cntr Div No = (937.500

÷

.0125) - (1171 x 64)

= 75,000 - 74,944
= 56

8.3 RECEIVER SERVICING

To isolate a receiver problem to a defective sec-

tion, start by checking the DC voltages shown in Sec-
tion 6.6.6 and on the schematic diagram (Section 10).
If that does not indicate the problem, perform the per-
formance tests in Section 7.2 to isolate the problem. If
the synthesizer is out of lock, the receiver is also non-
functional because the first injection and IF signals
will be incorrect.

8.4 TRANSMITTER SERVICING

To isolate a transmitter problem to a defective

section, start by checking the DC voltages shown in
Sections 6.6.4 and 6.6.6 and on the schematic diagram
(Section 10). If that does not indicate the problem,
perform the Performance Tests in Section 7.3, 7.4 and
7.5 to isolate the problem. If the synthesizer is out of
lock, the Exciter is also nonfunctional because the
software will not allow the repeater to transmit.

8.5 POWER SUPPLY SERVICING

The power supply is a switch mode type with

very high voltages. It is highly recommended that the
power supply be returned to the factory for servicing
(see Section 1.8). A parts list, schematic and compo-

Advertising