CIRCUIT DESCRIPTION

6-4

March 1999
Part No. 001-2009-600

Figure 6-3 SYNTHESIZER BLOCK DIAGRAM

(OPEN-DRAIN OUTPUT)

15

OUTPUT B

DATA OUT

24 BITS

A REGISTER

INPUT AMP

PRESCALER

64/65

in

f

in

f

10

11

LOGIC

MODULUS

CONTROL

N COUNTER

12-STAGE

A COUNTER

6-STAGE

CONTROL

INTERNAL

POR

LOGIC

STANDBY

8 BITS

C REGISTER

ENABLE

17

19

DATA IN

CLOCK

18

LOGIC

CONTROL

AND

REGISTER

SHIFT

16 BITS

R REGISTER

DOUBLE-BUFFERED

13-STAGE R COUNTER

DIVIDER

4-STAGE

OSC OR

out

REF

20

in

REF

1

OR (UP)

OV (DOWN)

16

OUTPUT A

LOGIC

SELECT

PORT

V

f

R

f

V

R

2

LOCK DETECT

AND CONTROL

LD

f

f

V

R

f

f

PHASE/FREQUENCY

DETECTOR B

AND CONTROL

PHASE/FREQUENCY

AND CONTROL

DETECTOR A

V

R

f

f

3

4

8

6

Rx

PDout

TEST 2

TEST 1

13

9

The programming of the counters in U205 is per-

formed by circuitry in the Main Processor Card
(MPC), buffered and latched through the Interface
Alarm Card (IAC) and fed in to the synthesizer on
J201, pin 20 to Data input port U205, pin 19.

Data is loaded into U205 serially on the Data

input port U205, pin 19 when U205, pin 17 is low.
Data is clocked into the shift registers a bit at a time
by a low to high transition on the Clock input port
U205, pin 18. The Clock pulses come from the MPC
via the IAC to J201, pin 19.

The counter divide numbers are chosen so the

TCXO-derived input to the phase detector (f

V

) is the

same frequency as the OCXO-derived input (f

R

). The

f

R

input is produced by dividing the 1.25 MHz OCXO

frequency by 125. This produces a reference fre-
quency (f

R

) of 10 kHz.

The f

V

input is produced by dividing the TCXO

frequency using the prescaler and N counter in U205.
The prescaler divides by 64 or 65. The divide number
of the prescaler is controlled by the N and A counters
in U205.

Both the N and A counters begin counting down

from their programmed number. When the A counter
reaches zero, it halts until the N counter reaches zero.
Both counters then reset and the cycle repeats. The A
counter is always programmed with a smaller number
than the N counter. While the A counter is counting
down, the prescaler divides by 65. Then when the A
counter is halted, the prescaler divides by 64. As an
example: To produce the frequency of 10 kHz, the N
and A counters are programmed as follows:

N = 27 A = 22