3 rf data, Figure 4-20 rf data, 4 input monitor – Viking 242-2009-632 User Manual

Page 67: Figure 4-21 input monitor, 5 revisions, Figure 4-22 revisions

Advertising
background image

LTR-Net PROGRAMMER

4-9

March 1999

Part No. 001-2009-600

4.5.3 RF DATA

Figure 4-20 RF DATA

The RF Line Monitor window shows the state of

the lines (see Figure 4-19). These lines are monitored
by the A-D converter in the IAC. The normal values
for each line are defined as follows.

Synthesizer Lock Lines:
Exciter Synthesizer

Yes, No

Receive Synthesizer

Yes, No

Exciter High Stability

Yes, No

Receive High Stability

Yes, No

Wideband Audio Output

approx. 200

LO Injection

approx. 200

RSSI

20-150

Fan 1 Current

100-200, 0

Fan 2 Current

100-200, 0

Transmit Parameters:
Forward Power (Low Power

25-75 Watts

Forward Power (High Power)

75-175 Watts

Reflected Power

0-6 Watts

Final Out 1-2 (ratio)

approx. equal

Final Out 3-4 (ratio)

approx. equal

Chassis Temp

27

°

C-55

°

C

Fan

On or Off

Power Supply Temp

22

°

C-45

°

C

Battery Voltage

21V-28V

Values with no label are the actual A-D reading.

To calculate the voltage on the line, divide the value
by 51. Example: Value

÷

51 = Volts. Any variation

from the above values may indicate a problem in that
area. Values in this window are relative measurements
only.

4.5.4 INPUT MONITOR

This window monitors the two Analog Input

lines. It is only used with the 4-Alarm Type IAC, and
only if Input 3, Input 4 or both are programmed for
"Analog". In addition to the actual or measured value,
the Low/High limit data are also displayed. These
limits are programmed in the "Edit -> Repeater Infor-
mation -> Input Alarms" screen (see Figure 4-13). If
one of these inputs is not programmed "Analog", the
data for that input is blanked.

Figure 4-21 INPUT MONITOR

4.5.5 REVISIONS

This menu selection has an equivalent icon in
the toolbar. This menu selection or icon dis-
plays the current firmware revision informa-

tion for the MPC, MAC and HSDB. The format is R.V
(revision.version) for all modules. The MPC informa-
tion also includes the release date of the software and
the serial number of the repeater. The HSDB version in
Figure 4-22 is for J4, pins 5-6 connected in the MPC for
LTR-Net (J4, pins 3-4 connected in the MPC are for
standard LTR).

Figure 4-22 REVISIONS

Advertising