Wayne ESP45 User Manual

Page 6

Advertising
background image

6

Operating Instructions and Parts Manual

TROUBLESHOOTING CHART

Symptom

Possible Cause(s)

Corrective Action

Pump won't run

1. Connections not secure

2. Low or defective battery

3. Float switch stuck

4. Defective or blown fuse

1. Check all connections

2. Check battery and replace if low or defective

3. Make sure nothing is interfering with operation of switch

4. Check internal fuse located on the PS/BC. Pull the charger

from the wall outlet and remove. If the fuse is blown, replace
it with an automotive type fuse of the same amp ratio.

Motor hums but
pump won't run

1. Defective battery

2. Impeller is locked

1. Check battery and replace if low or defective

2. Unplug pump, volute, and check to see if impeller is free

to turn. If impeller is locked, remove the obstruction.
Reassemble pump and reconnect

Pump runs but
pumps very little
or no water

1. Check valve missing or

improperly installed

2. Obstruction in discharge pipe or

pump inlet

3. Discharge pipe length and/or

height exceeds capacity of pump

4. Low or defective battery

1. Check to make sure check valves installed between primary

pump discharge and Backup Sump Pump are functioning
properly

2. Check for obstruction and clear if necessary

3. If discharge is too high, a separate line may be required with

a lower discharge height

4. Check battery and replace if low or defective

Pump cycles too
frequently

1. Check valve problem

1. Check to make sure check valves installed between primary

pump discharge and Backup Sump Pump are functioning
properly

No yellow light

1. Battery connection problem

1. Verify battery connection is correct

Red light is on
with alarm

1. Blown pump fuse

2. Low battery voltage

1. Check fuse and replace with a fuse of same rating and size

2. Check battery voltage. PS/BC will not charge batteries with a

combined voltage of 21.6 VDC or less

www.waynepumps.com