Caution – White Rodgers 1F95-71 User Manual

Page 14

Advertising
background image

14

ADJUSTABLE HEATING AND COOLING

CYCLE TIMES (ANTICIPATION) — If the
heating/cooling system is turning on and off
too often (short cycles) or not often enough
(long cycles), you may want to adjust the
anticipation setting.

A cooling anticipation setting of less
than 10 may cause decreased com-
pressor life.

To adjust anticipation, press

SET

CLOCK

and

ADV
DAY

at the same time. The display will show
HEAT 8 (this is the factory preprogrammed
heating anticipation setting). You may se-
lect any anticipation setting from 4 to 40. If

the heat cycles are too short, press

TIME
FWD

to

increase the cycle time. If the heat cycles

are too long, press

TIME

BACK

to decrease the

cycle time. To set cooling anticipation, press

SET

CLOCK

and

ADV
DAY

at the same time again. The

display will show COOL 14 (factory prepro-

grammed cooling anticipation). Use

TIME
FWD

and

TIME

BACK

to adjust anticipation. Press

RUN

PRGM

to return to your program.

LOW BATTERY INDICATOR — The word

BATTERY will flash on the display if the 9
volt alkaline battery is low and should be
replaced.

CAUTION

!

Advertising