8. Test Boot Commands: When the NPS-2HD is powered

up, both switched plugs will be set in the ON position. In

order to test for proper operation, you may wish to perform

the following test. Note that it is not necessary to connect

a device to either switched outlet in order to perform

this test.
a) Reboot Plugs: To initiate a boot cycle at both plugs,

go to the NPS command prompt and type /BOOT *

and press [Enter]. Power to both plugs will be

switched OFF. After the Boot Delay Period (Default =

5 Seconds), the power to both plugs will then be

automatically switched back ON. Note that the Plug

Status Indicators on the NPS-2HD front panel will also

switch Off and On.

b) Switch Plugs OFF: To switch both plugs OFF, go to

the NPS command prompt, type /OFF * and then

press [Enter]. Power to both plugs will be switched

OFF. Note that the Plug Status Indicators will also be

switched Off.

c) Switch Plugs ON: To switch both plugs ON, go to the

NPS command prompt, type /ON * and then press

[Enter]. Power to both plugs will be switched ON.

Note that the Plug Status Indicators will also be

switched On.

9. Exit Command Mode: Type /X and press [Enter] to exit

from the NPS Command Mode, or disconnect using your

Telnet program.

This completes the introductory overview of the NPS-2HD.

Prior to installing and operating the unit, please review the

remainder of this User's Guide for important information

regarding safety considerations, as well as more detailed

installation, configuration, and operation instructions.

3-4

NPS-2HD Heavy Duty Network Power Switch; User's Guide