Operating your thermostat, Important, Installer/configuration menu – White Rodgers 1F85CA-0471 User Manual

Page 7: Programming (for programmable model only)

Advertising
background image

7

OPERATING YOUR THERMOSTAT

Choose the Fan Setting (Auto or On)

Press the FAN button to Auto or On.
Fan Auto is the most commonly selected setting and runs the
fan only when the heating or cooling system is on.
Fan On runs the fan continuously for increased air circulation
or to allow additional air cleaning.

Choose the System Setting
(Heat, Off, Cool, Auto, Emer)

Press the SYSTEM button to select:

Heat: Thermostat controls only the heating system.

Off: Heating and Cooling systems are off.

Cool: Thermostat controls only the cooling system.

Auto: Auto Changeover is used in areas where both heating
and cooling may be required on the same day. AUTO allows
the thermostat to automatically select heating or cooling
depending on the indoor temperature and the selected heat
and cool temperatures. When using AUTO, be sure to set the
Cooling temperatures more than 1° Fahrenheit higher than
the heating temperature.

Emer: (Heat Pump models) Thermostat controls only backup
heating system.

IMPORTANT!

Manual Operation for Non-Programmable
Mode

Press the SYSTEM button to select Heat or Cool and use
the

or

buttons to adjust the temperature to your

desired setting. After selecting your desired settings you can
also press the SYSTEM button to select AUTO to allow the
thermostat to automatically change between Heat and Cool.

Manual Operation (Bypassing the Program)
Programmable Thermostats

Press

or

and then the HOLD button and adjust the

temperature wherever you like. This will override the program.
The HOLD feature bypasses the program and allows you
to adjust the temperature manually, as needed. Whatever
temperature you set in HOLD will be maintained 24 hours
a day, until you manually change the temperature or press
Run Sched to cancel HOLD and resume the programmed
schedule.

Program Override (Temporary Override)

Press

or

buttons to adjust the temperature. This

will override the temperature setting for two hours minimum
or until the next programmed time. To cancel the temporary
setting at any time and return to the program, press Run
Sched.
If the SYSTEM button is pressed to select AUTO
the thermostat will change to Heat or Cool, whichever ran
last. If it switches to heat but you want cool, or it changes
to cool but you want heat, press both

and

buttons

simultaneously to change to the other mode.

INSTALLER/CONFIGURATION MENU

20) Comfort Alert with Active Protection – Turn this

feature ON to enable active protection. This allows the
thermostat to identify fault codes sent by the Comfort
Alert module when compressor damage is possible and
react to those codes by turning the compressor off. Fault
codes from the Comfort Alert module will fl ash on the
thermostat. (Refer to Comfort Alert Yellow Alert Codes
in Troubleshooting section.) If a Comfort Alert module is
not connected, or to disable active protection, turn this
feature OFF. If a Comfort Alert module is connected and
this feature is turned OFF, the thermostat will still receive
and fl ash the fault codes from the Comfort Alert module,
but the active protection will not be enabled to protect the
compressor.

21) Select Daylight Saving Time Calculation – Not avail-

able on 1F83, this feature will allow the thermostat to
calculate the DST automatically and apply it to the Real
Time Clock display. Default On. Use

or

buttons

to select the feature OFF.

22) Select Filter Replacement Reminder and Set Run

Time – Select the “Change Filter” reminder On or
OFF. If selected On, press MENU to select the time
period from 25 to 1975 hours in 25 hours increments.
In a typical system, 200 hours (default) of run time is
approximately 30 days. After the selected time of blower
operation, the thermostat will display “Change Filter”
as a reminder to change or clean your air fi lter. When
“Change Filter” is displayed, press MENU or RUN
SCHED
button to clear the display and restart the time to
the next fi lter change.

23) Select Reversing Valve Output – The O/B option is

factory set at “O” position. This will accommodate the

majority of heat pump applications, which require the

changeover relay to be energized in COOL. If the
thermostat you are replacing or the heat pump being
installed with this thermostat requires a “B” terminal, to
energize the changeover relay in HEAT, the O/B option
should be set at “B” position.

PROGRAMMING (For Programmable Model Only)

Set Current Time and Date

1) Press Menu and then Time button once. The display

will show the hour only.

2) Press and hold either the

or

button until you

reach the correct hour and AM/PM designation (AM
begins at midnight, PM begins at noon).

3) Press Time once again. The display window will show

the minutes only.

4) Press and hold either the

or

button until you

reach the correct minutes.

5)

Additional presses of Time will advance the display to
show the year, month and date of month. Press the
or

button to change the display to the correct set-

ting for each.

6) Press Run Sched to exit the Time mode.

Advertising
This manual is related to the following products: