Wolf Appliance Company GAS COOK TOPS User Manual

Page 9

Advertising
background image

9

Dimensions in parentheses are in
millimeters unless otherwise specified.

I N S TA L L AT I O N

I N S T R U C T I O N S

V E N T I L AT I O N

O P T I O N S

IMPORTANT NOTE: It is recommended that
you operate the Wolf gas cooktop with either a
Wolf cooktop ventilation hood, downdraft
system or Pro ventilation hood. Contact your
Wolf dealer for details.

Cooktop Wall Hood – 30" (762) or 36" (914)
widths in classic stainless steel.

Cooktop Island Hood – 42" (1067) width in
classic stainless steel.

Downdraft Ventilation System – 30" (762),
36" (914) or 45" (1143) widths, with top
cover and control panel in classic, platinum
and carbon stainless steel finishes (45"
downdraft available in classic finish only).

Pro Wall Hood – 22" (559), 24" (610) or 27"
(686) depths and 30" (762) to 66" (1676)
widths in classic stainless steel.

Pro Island Hood – 36" (914) to 66" (1676)
widths in classic stainless steel.

Pro Hood Liner – available in widths to
accommodate 30" (762) to 60" (1524) hood
shells.

All hoods have welded seams, sealed halogen
lighting and removable, dishwasher-safe
filters.

Blower requirements may vary due to the
length of ducting and number of angles. The
basic recommendation is 1 CFM per 100 Btu/hr
(.03 kW). Always consult your HVAC profes-
sional for more concise blower requirements.

IMPORTANT NOTE: When installing a ventila-
tion hood, refer to the specific requirements
of the hood for the minimum dimension to
countertop.

I N S TA L L AT I O N

O P T I O N S

M U L T I P L E C O O K T O P I N S T A L L A T I O N

If the gas cooktop is to be used with any
combination of additional cooktop units or
modules with a filler strip, the cut-out width is
calculated by adding the corresponding units'
cut-out dimensions plus 1

1

/

4

" (32) for each

additional unit. Refer to the illustration below.

IMPORTANT NOTE: When multiple units are
installed side by side, each unit must have its
own separate recommended electrical circuit.
When multiple gas units are installed next to
one another, they can receive their gas supply
from a common line. However, each unit
MUST have its own regulator installed
between the mainline and the gas cooktop.

When two or more modules are installed
together, an integrated module filler strip
(IFILLER/S) is recommended. If a downdraft
ventilation system is also installed, an inte-
grated module support for downdraft ventila-
tion (ISUPPORT) is also required (Model DD30
only). Contact your Wolf dealer for information
on these accessory components.

2

1

/

2

"

min

(64)

FRONT OF COUNTERTOP

19

1

/

4

"

(489)

CUT-OUT

DEPTH

29

1

/

4

"

(743)

TWO MODULES WIDTH

44

1

/

2

"

(1130) THREE MODULES WIDTH OR

44

1

/

4

"

(1124) 30" COOKTOP AND ONE MODULE

59

3

/

4

"

(1518) FOUR MODULES WIDTH OR

59

1

/

2

"

(1511) 30" COOKTOP AND TWO MODULES OR

50

1

/

4

"

(1276) 36" COOKTOP AND ONE MODULE

14"

(356)

CUT-OUT

WIDTH

Countertop cut-out dimensions for installation of multiple cooktops

O P T I O N A L
I N S T A L L A T I O N S