background image

4.2. Configure SetUp Switches

The SetUp Switches are used to select default settings for the APS RS232 ports. On model

APS-16 , the SetUp Switches are located on the underside of the unit. On APS-8 and APS-4

models, the SetUp Switches are located on the instrument

back panel.
When the APS is shipped from the factory, the SetUp Switches are configured for 9600 baud, 8

Bits-No Parity, RTS/CTS handshaking, verbose command response, and command echo on (all

switches ON). These settings are compatible with most applications. If the default settings are

not compatible with your application, change the switch settings as follows.

Notes:

• The SetUp Switches should be configured to match the parameters your control

device will use when communicating with the APS. This will ensure access to

command functions, even if the unit is initialized to default parameters.

• If the SetUp Switch configuration is changed, new parameters will not take effect

until the unit is initialized as described in Section 4.3.

• Operating parameters (baud rate, parity, etc.) can be selected for each port using

the /P command as described in Section 5.5. The /P command can select different

parameters for each APS port.

• When the APS is initialized, parameters will return to settings specified by the

SetUp Switches.

On/Off Positions: On the APS-8 and the APS-4 (Switches on Back Panel), the switches are

ON when placed in the DOWN position. On the APS-16 (Switches on underside of unit)

On/Off positions are indicated on a label adjacent to the SetUp Switches.

4.2.1.

Default Baud Rate (Sw1, Sw2, Sw3)

SetUp Switches one through three select the default baud rate for all APS RS232 Ports. The

default baud rate must match the rate your control device will use when communicating with

the APS. If the control device will communicate via modem, select a default baud rate that is

compatible with the modem. Note that the /P command can also be used to select a different

operating baud rate for each port.

SW

Default Baud Rate

1

2

3

ON

ON

ON

9600*

OFF

ON

ON

300

ON

OFF

ON

1200

OFF

OFF

ON

2400

ON

ON

OFF

19.2K

OFF

ON

OFF

38.4K

ON

OFF

OFF

57.6K

OFF

OFF

OFF

115.2K

* = Factory Setting

4-2

APS Series - Asynchronous Port Switches, User's Guide

Hardware Installation