Western Telematic APS-16 User Manual

Page 38

Advertising
background image

7.4. Modem Mode

In addition to allowing data transfer, the Modem Mode also provides additional functions

specifically related to modem communication. A Modem Mode Port can perform all functions

normally available in Any-to-Any Mode. The Modem Mode is available to all APS RS232

ports.
When the Modem Mode is selected, the port configuration menu (command /P) will display

three additional prompts, which allow the user to re-define the modem reset string,

initialization string, and hang-up string.
When the Modem Mode is selected for a port with Supervisor Level command access, the

Supervisor Password should be defined. This will discourage unauthorized access to higher

command functions.
When a call is received, the unit will prompt the caller to enter a password. The APS allows

three attempts to enter a valid password. If the correct password is not entered in three

attempts, or if the user does not respond to the password prompt within 30 seconds, the modem

will disconnect.
The password can be defined and enabled by invoking the /P command as described in

Section 5.5.

Notes:

• When a Modem Mode Port exits Command Mode, or the DCD line is lost while

the Command Mode is active, the APS will pulse the DTR line to the modem.

The unit will then send the user-defined modem command strings to make certain

the modem is properly disconnected and reinitialized.

• When an external modem is installed at a APS port, other ports can use the

modem for calling out. To call out, invoke the /C command to connect to the port,

and then access the modem as you normally would.

7-6

APS Series - Asynchronous Port Switches, User's Guide

Operation

Advertising