5.5.3.

RS232 Port Configuration Menus

The Port Configuration Menus are used to select options for each of the APS RS232 ports.

Parameters selected via these menus will stay in effect until the unit is initialized or the /P

command is used to reconfigure the port. After initialization, parameters will revert to the

defaults specified by the SetUp Switches.
To select port parameters, proceed as follows:

1. Access the Command Mode. If the password prompt is displayed, key in your Supervisor

Level Password.

2. Type /P, followed by the number of the port to be configured, and press [Enter]. For

example, to configure Port 2, type /P 2 [Enter]. The Port Configuration menu will

appear (Figure 5.1).
a) If the /P Command is entered without the port number (e.g. /P [Enter]), the

configuration menu for your resident port will be displayed.

b) The /P command is only available in the

Supervisor Mode

5-5

APS Series - Asynchronous Port Switches, User's Guide

Configuration

PORT PARAMETERS #02

1.

Port Name:

(undefined)

2.

Password:

(undefined)

3.

Baud Rate:

9600

4.

Bits/Parity:

8-None

5.

Stop Bits:

1

6.

Handshake Mode:

CTS/RTS

7.

Port Mode:

Any-to-Any

74.

DTR Output:

Pulse

8.

Supervisor Mode:

Permit

9.

Logoff Character:

^X

10.

Sequence Disconnect:

One Character

11.

Timeout Disconnect:

Off

12.

Response Type:

Verbose

13.

Command Echo:

On

14.

Accept Break:

Yes

Enter:

"<" Previous Port,

">" Next Port,

<ESC> Exit ...

Figure 5.1: Port Configuration Menu (Port 2 Shown)