A cooling anticipation setting of less
than 10 may cause decreased compres-
sor life.

To adjust heat anticipation, press

SET

CLOCK

and

SET

DAY

at the same time. The display will

show HEAT 5 (this is the factory prepro-
grammed heating anticipation setting). You
may select any anticipation setting from 2 to
40 (note that for hydronic systems, a
minimum anticipation setting of 15 is
recommended
). Whenever adjusting an-
ticipation, increase or decrease the dis-
played number by only one or two digits,
then let the system run for a while to see if
the adjustment is sufficient. If the heat

cycles are too short, press

TIME

FWD

to increase

the cycle time. If the heat cycles are too long,

press

TIME

BACK

to decrease the cycle time. To

set cooling anticipation, press

SET

CLOCK

and

SET

DAY

at the same time again. The display will

show COOL 14 (factory preprogrammed cool-

ing anticipation). Use the

TIME

FWD

and

TIME

BACK

buttons to adjust anticipation. Press

RUN

PRGM

to

return to your program.

LOW BATTERY INDICATOR — The word

BATTERY will flash on the display if the
"AA" alkaline batteries are low and should
be replaced. The word BATTERY will be
displayed continuously (non-flashing) when
24v AC power is not being supplied to the