Windows Marketplace V.90 User Manual

Page 53

Advertising
background image

53

ever, may be affected by some ATX options according to country restrictions.

Range:

2-65

Default:

2

Units:

seconds

S7

Connection Completion Time-Out

This register sets the time, in seconds, that the modem must wait before hanging

up because carrier is not detected. The timer is started when the modem finishes

dialing (originate), or goes off-hook (answer). In originate mode, the timer is reset

upon detection of an answer tone if allowed by country restriction. The timer also

specifies the wait for silence time for the @ dial modifier in seconds. S7 is not

associated with the W dial modifier.

Range:

1-255

Default:

50

Units:

seconds

S8

Comma Dial Modifier Time

This register sets the time, in seconds, that the modem must pause when it encoun-

ters a comma (,) in the dial command string.

Range:

0-65

Default:

2

Units:

seconds

S10

Automatic Disconnect Delay

This register sets the length of time, in tenths of a second, that the modem waits

before hanging up after a loss of carrier. This allows for a temporary carrier loss

without causing the local modem to disconnect. The actual interval the modem

waits before disconnecting is the value in register S10.

Range:

1-254

Default:

20

Units:

0.1 seconds

S11

DTMF Dialing Speed

This register determines the dialing speed which is prefixed for each country.