Unobstructed Airflow

Unobstructed airflow too and from the unit is critical for the unit’s overall performance and life-span. A mini-

mum three-foot clearance (five foot is ideal) area is crucial. The air the fans blow needs to circulate and either dissi-

pate or absorb heat from the space, the more air to exchange the more efficient the system will operate.

Note: Avoid attempting to camouflage the unit. This will restrict airflow and thus the unit’s ability to work efficiently.

Door and Door Seal

An exterior grade (1 3/4”) door must be installed as a cellar door. It is very important that weather stripping is at-

tached to all 4 sides of the doorjamb. A bottom “sweep” or threshold is also required. The door must have a very good

seal to keep the cool cellar air from escaping out of the cellar. One of the most common problems with cooling units

running continually is due to the door not sealing properly.

Mounting the Unit

The unit must be mounted within 18“ of the top of the room in order to achieve sufficient cooling. As the room cools

down, the warm air will rise to the ceiling. Mounting the WhisperKOOL high in the room will create a consistently

cool environment by capturing the warm air and replacing it with cool air. Mounting the unit low in the room will

result in a temperature variation in the room due to the unit’s inability to draw warm air from the ceiling of the cellar

to the unit itself, and cold air settling to the floor.

Wine Cellar

Exhaust Area

Keep Clear

Exhaust Fan/Vent

(optional)

Air Intake

(optional)