Installation – WhisperKool 2500 User Manual

Page 14

Advertising
background image

Page 12

SL 082411

STEP 4

Slide the cooling unit in from the cellar side with the

thermostat facing inside. The outer flange should be flush

to the wall. Secure the flange to the wall through the

pre drilled holes. The screws should penetrate the studs

and/or frame as well as the upper and lower supports to

provide adequate support for the WhisperKOOL system.

Seal all cracks and gaps around the unit with an air-tight

sealant or caulking to prevent air leakage.

Note: If you use decorative molding, it should be attached to
the walls and never to the cooling unit.

STEP 5

Attach the condensate drain line

The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge loca-

tion. It is important that the drain line tube is properly connected and used to prevent leakage and other problems

associated with excess condensation.

Failure to use the condensation drain line tube will void the warranty on the unit.

Note: To prevent mold from growing, allow the drain line to
hang above the water line.

Failure to install the drain line voids warranty.

To prevent mold from growing, allow the drain line to
hang above the water line.

STEP 6

If removed, install the grille’s on both sides of the unit and plug in the power cord. The use of an extension cord is not

recommended.

Drain line is

above possible

water level

INSTALLATION

CELLAR SIDE

Bottle Probe

Power

Drain line

WRONG: Drain line

is under water.