Alarm codes – WhisperKool 2500 User Manual

Page 18

Advertising
background image

Page 16

SL 082411

SET 1. Press the “Set” button once and it will display the Set Point. After approximately 5 sec-

onds, the display will return to normal operation and display the Bottle Probe tempera-

ture.

2. Standard Controller - Press and hold the “Set” button for 3-5 seconds until the set point

is displayed and the °F symbol starts blinking. Next press the “UP or Down” arrows to

change the Set Point. Next press the “Set” button once and the Set Point numbers and

the °F on the display will blink to confirm the new Set Point setting.

3. Press and hold the “Set” button during the display of the Hi/Low “Temperature Data His-

tory” (hold button unit “rst” blinks on display), and it will erase the past recorded data file

and start recording, from the current time and temperature.

4. Press the “Set” and the “Down Arrow” buttons simultaneously, for 10-15 seconds, and

you will access the “Customer Preference Selection Mode” (CPSM). The CPSM allows the

customer to “Fine Tune” the Control Operating System to their applicable choice.

Anti-Frost The Anti-Frost Cycle is automatically activated when the evaporator temp has reached a low

temp of 26° and has sustained that temp for a period of five minutes. During this cycle the

compressor and condenser fans will turn off and the evaporator fans will continue to run.

Once the temperature of the evaporator gets back up to 40° the cycle will deactivate and

the system will revert back to normal operating conditions.

At the beginning of the cycle the symbol will be illuminated and the symbol is

illuminated during the anti-frost cycle.

Alarm The Alarm symbol is shown when the system encounters an issue that needs attention, the

displayed alarm codes are explained below.

Alarm Codes

Message

Cause

Solution

“P1”

Bottle Probe is Unplugged

Attach Bottle Probe to Unit

Faulty Bottle Probe Connection

1. Check Bottle Probe attachment at circular connector

2. Check Bottle Probe connection at green terminal block on

back of controller

Defective Bottle Probe

Replace the Bottle Probe

“P2”

Faulty Evaporator Probe

Connection

Check Evaporator Probe connection at green terminal block on back of

controller

Defective Evaporator Probe

Replace the Evaporator Probe

“HA”

Defective Bottle Probe

Replace the Bottle Probe

“LA”

The Bottle Probe is sensing a

temperature of 4° below the set

point

Allow the room to warm up which will increase the temperature of the

wine

Defective Bottle Probe

Replace the Bottle Probe

“POF”

The keypad is locked

Hold “Up” and “Down” buttons for 3 to 5 seconds to disable, “PON”

should appear

Advertising