Crossover Ignition System Operations

If the Crossover Ignition System fails to ignite the Front
burner, light the Front burner with a match. If the Front
burner lights with a match, then check the Crossover
Ignition System.

Check that both the white and black ignition wires
are attached properly. Figure 24.

Check that the Crossover Ignition button pushes the
igniter (button) down, and returns to the up position.

Check to see if the igniter is loose in the frame.
Tighten if necessary; see Step “Install igniter” for
correct procedure.

If the Crossover Ignition System still fails to light, contact
your dealer.

Figure 24

15. Reinstall the Spider Stopper Guards. Slightly rotate

the Spider Stopper Guards so that the seams are in
line with the Venturi fins. There should be no gaps
in the seams or in the fit around the burners and
valves. Figure 23.

ƽ

CAUTION: If the Spider Stopper Guards do not fit

tightly, contact Weber-Stephen Customer Service.

ƽ

CAUTION: After reinstalling the gas lines, they

should be leak checked with a soap and water
solution before using the barbecue. See Step“Check
for gas leaks”.

Venturi fin

Figure 23

Check fit
around valve

Check fit around burner

13. Lift and twist the burner assembly slightly to

separate the crossover tube from the burners.
Remove the burners from the cooking box.
Figure 21.

Figure 21

Separate here

Crossover tube

14. To reinstall the burners, reverse steps 3 through 13.

ƽ

CAUTION: The burner openings must be

positioned properly over the valve orifices.
Figure 22a.

Check proper assembly before fastening manifold in
place. Figure 22b.

Figure 22

(a)

(b)

Valve

Burner