C: s – Westinghouse SE 6000 User Manual

Page 159

Advertising
background image

#

Message

Explanation

C-2

A

PPENDIX

C: S

YSTEM

T

RANSACTIONS

— N

UMERICAL

S

EQUENCE

29

Printer On

Log printer switched on.

30

Device Reset

708P / 8xx-series powered up / re-initialized.

31

Return From Failsoft

708P communication restored — no longer in failsoft mode.

32

Power Failed

708P / 8xx-series with 3708 UPS has lost AC power.

33

Power Restored

708P / 8xx-series with 3708 UPS has regained AC power.

34

Tamper Active

708P / 8xx-series tamper input active.

35

Tamper Clear

708P / 8xx-series active tamper input now cleared.

36

COAX Failure

Coax cable from ACU to reader shorted.

37

COAX OK

Coax cable from ACU to reader repaired.

38

Sensor Failure

ACU has lost communication with reader (open coax).

39

Sensor OK

Previously failed reader (or open coax) repaired.

40

Printer Error

Log printer is not functioning properly.

41

Poller Params Reloaded

Host has initialized a poller.

42

Still Held Open

DOOR HELD OPEN — Second alert message.

43

Input Point Active

A GENERAL input has been activated.

44

Input Point Normal

Previously activated GENERAL input point has been cleared.

45

Timeout Device

Response from polled ACU by host not received within allotted time
(usually 2 seconds).

46

Unable to Lock Door

Host unable to implement automatic or manual command to lock a

door (error on lock).

47

Unable to Unlock Door

Host unable to implement automatic or manual command to unlock
a door (error on unlock).

48

Unable to Clear Output

Host unable to restore output contact to normal (error on output

clear).

49

Unable to Act. Output

Host unable to restore output contact to active (error on output

clear).

50

Not Used

Reserved for future applications.

51

Not Used

Reserved for future applications.

52

Manual Unlock Timed

Timed unlock command entered.

53

Manual Access Granted

Manual access command issued.

Advertising