Zebra Technologies Z6Mplus User Manual
Page 122

104
Z4Mplus/Z6Mplus User Guide
13163L Rev. 3 5/20/2004
Data Connections
Serial Data Port
RS-232 Interface Connections
The printer is configured as Data Terminal Equipment (DTE).
shows the internal
connections of the printer’s RS-232 connector.
Figure 44 • RS-232 Internal Connections
When the printer is connected via its RS-232 interface to Data Communication Equipment
(DCE) such as a modem, use a standard RS-232 (straight-through) interface cable.
illustrates the connections required for this cable.
Figure 45 • RS-232 to DCE Internal Connections
Note •
Use a a null modem (crossover) cable to connect the printer to a computer or any other
DTE devices.
1
(TD)
(TD)
(RD)
(RD)
(RTS)
(RTS)
(DSR)
(DSR)
(SG)
(SG)
(DTR)
(DTR)
DTE
DTE
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
DTE
(Printer)
DCE
(Modem, etc.)
RXD (receive data)
TXD (transmit data)
DTR (data terminal ready)
SG (signal ground)
DSR (data set ready)
RTS (request to send)
CTS (clear to send)
+5 VDC signal source
NOTE • Pin 1 is unused and unterminated at the printer.
2
3
4
5
6
7
8
9
2
3
4
5
6
7
8
9